Modelling of Operation PMSG Based on Fuzzy Logic Control under Different Load Conditions

In order to reduce energy cost, the use of renewable energy sources have been attracted worldwide. Therefore, wind energy conversion systems (WECS) have gained importance among renewable energy methods. Permanent magnet synchronous generators (PMSG) are widely used in wind power system due to generated electrical power from low speed of wind and can be operated in the variable wind speed. Unbalanced load or different load conditions effect PMSG operation system. Furthermore, these conditions occur in problematic operation and distorted converter currents. In this study, a fuzzy logic control system is implemented to analyse power flow efficiency of PMSG. An 850-kW PMSG system based on the WECS is built in Matlab/Simulink. The control system performance of the PMSG system is investigated in different load conditions and the operation of PMSG are comprehensively analysed. The performed analyses showed that the proposed model can be robustly utilized under different operation conditions.